A DATA HALLS B COOLING C ACCESS · CAR PARK D POWER SUPPLY
lx °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C mm kW %/m bar IO mm kW %/m bar IO mm kW %/m bar IO kW V kW % % % °C m³/h % m³/h
Data flow Sensors
LIVE SENSORLIGHT_04
Ambient light 52 lx Datacenter roof
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: light < 25 lx → lighting on Send reading now LIVE SENSORRACK_101
Rack 1.01 · level 1 Inlet air23.4 °C Outlet air35.6 °C Humidity48% PDU load13.2 kW ΔT12.3 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_102
Rack 1.02 · level 1 Inlet air25.1 °C Outlet air36.1 °C Humidity45% PDU load10.0 kW ΔT11.0 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_103
Rack 1.03 · level 1 Inlet air24.6 °C Outlet air36.2 °C Humidity42% PDU load11.4 kW ΔT11.6 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_104
Rack 1.04 · level 1 Inlet air24.1 °C Outlet air36.2 °C Humidity47% PDU load12.8 kW ΔT12.1 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_105
Rack 1.05 · level 1 Inlet air23.6 °C Outlet air34.4 °C Humidity44% PDU load9.6 kW ΔT10.8 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_106
Rack 1.06 · level 1 Inlet air23.1 °C Outlet air34.5 °C Humidity41% PDU load10.9 kW ΔT11.4 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_107
Rack 1.07 · level 1 Inlet air24.9 °C Outlet air36.8 °C Humidity46% PDU load12.3 kW ΔT11.9 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_108
Rack 1.08 · level 1 Inlet air24.4 °C Outlet air36.8 °C Humidity43% PDU load13.6 kW ΔT12.5 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_109
Rack 1.09 · level 1 Inlet air23.9 °C Outlet air35.1 °C Humidity48% PDU load10.5 kW ΔT11.2 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_110
Rack 1.10 · level 1 Inlet air23.4 °C Outlet air35.1 °C Humidity45% PDU load11.8 kW ΔT11.7 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_201
Rack 2.01 · level 2 Inlet air24.6 °C Outlet air36.0 °C Humidity42% PDU load10.9 kW ΔT11.4 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_202
Rack 2.02 · level 2 Inlet air24.1 °C Outlet air36.0 °C Humidity47% PDU load12.3 kW ΔT11.9 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_203
Rack 2.03 · level 2 Inlet air23.6 °C Outlet air36.1 °C Humidity44% PDU load13.6 kW ΔT12.5 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_204
Rack 2.04 · level 2 Inlet air25.4 °C Outlet air36.6 °C Humidity41% PDU load10.5 kW ΔT11.2 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_205
Rack 2.05 · level 2 Inlet air24.9 °C Outlet air36.6 °C Humidity46% PDU load11.8 kW ΔT11.7 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_206
Rack 2.06 · level 2 Inlet air24.4 °C Outlet air36.6 °C Humidity43% PDU load13.2 kW ΔT12.3 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_207
Rack 2.07 · level 2 Inlet air23.9 °C Outlet air34.9 °C Humidity48% PDU load10.0 kW ΔT11.0 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_208
Rack 2.08 · level 2 Inlet air25.6 °C Outlet air37.2 °C Humidity45% PDU load11.4 kW ΔT11.6 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_209
Rack 2.09 · level 2 Inlet air25.1 °C Outlet air37.2 °C Humidity42% PDU load12.8 kW ΔT12.1 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_210
Rack 2.10 · level 2 Inlet air24.6 °C Outlet air35.4 °C Humidity47% PDU load9.6 kW ΔT10.8 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_301
Rack 3.01 · level 3 Inlet air25.9 °C Outlet air38.1 °C Humidity44% PDU load13.2 kW ΔT12.3 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_302
Rack 3.02 · level 3 Inlet air25.4 °C Outlet air36.4 °C Humidity41% PDU load10.0 kW ΔT11.0 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_303
Rack 3.03 · level 3 Inlet air24.9 °C Outlet air36.4 °C Humidity46% PDU load11.4 kW ΔT11.6 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_304
Rack 3.04 · level 3 Inlet air24.4 °C Outlet air36.5 °C Humidity43% PDU load12.8 kW ΔT12.1 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_305
Rack 3.05 · level 3 Inlet air26.1 °C Outlet air36.9 °C Humidity48% PDU load9.6 kW ΔT10.8 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_306
Rack 3.06 · level 3 Inlet air25.6 °C Outlet air37.0 °C Humidity45% PDU load10.9 kW ΔT11.4 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_307
Rack 3.07 · level 3 Inlet air25.1 °C Outlet air37.0 °C Humidity42% PDU load12.3 kW ΔT11.9 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_308
Rack 3.08 · level 3 Inlet air24.6 °C Outlet air37.1 °C Humidity47% PDU load13.6 kW ΔT12.5 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_309
Rack 3.09 · level 3 Inlet air24.1 °C Outlet air35.3 °C Humidity44% PDU load10.5 kW ΔT11.2 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORRACK_310
Rack 3.10 · level 3 Inlet air25.9 °C Outlet air37.6 °C Humidity41% PDU load11.8 kW ΔT11.7 K DoorsClosed
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: inlet air > 30 °C → alarm and more cooling water Send reading now LIVE SENSORLEAK_01
Leak detection · level 1 Water0 mm Place on the cable– Cable length42 m
Reports on every change
Via · LoRaWAN
Last received –
Used for Rule: water under the floor → alarm and the loop's valve closed Send reading now LIVE SENSORRPP_01
Row power panel · level 1 Load116.3 kW L1177 A L2167 A L3162 A Capacity used73% Branches10 / 10
Reports every minuteevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: branch > 90% → overload alarm · phase balancing Send reading now LIVE SENSORSMOKE_01
Smoke · level 1 Obscuration0.02 %/m Temperature rise0.1 °C/min StateClear
Reports on every change
Via · LoRaWAN
Last received –
Used for Rule: smoke or a sudden temperature rise → alarm and suppression armed Send reading now LIVE SENSORGAS_01
Gas suppression · level 1 Pressure42 bar StateArmed Cylinders4 / 4
Reports every 15 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Measurement history and trends Send reading now LIVE SENSORDOOR_01
Door · cooling plant DoorClosed People inside1 Last entry13:42
Reports on every change
Via · LoRaWAN
Last received –
Used for Physical security · log of entries and presence Send reading now LIVE SENSORLEAK_02
Leak detection · level 2 Water0 mm Place on the cable– Cable length42 m
Reports on every change
Via · LoRaWAN
Last received –
Used for Rule: water under the floor → alarm and the loop's valve closed Send reading now LIVE SENSORRPP_02
Row power panel · level 2 Load116.3 kW L1177 A L2167 A L3162 A Capacity used73% Branches10 / 10
Reports every minuteevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: branch > 90% → overload alarm · phase balancing Send reading now LIVE SENSORSMOKE_02
Smoke · level 2 Obscuration0.02 %/m Temperature rise0.1 °C/min StateClear
Reports on every change
Via · LoRaWAN
Last received –
Used for Rule: smoke or a sudden temperature rise → alarm and suppression armed Send reading now LIVE SENSORGAS_02
Gas suppression · level 2 Pressure42 bar StateArmed Cylinders4 / 4
Reports every 15 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Measurement history and trends Send reading now LIVE SENSORDOOR_02
Door · power room DoorClosed People inside1 Last entry13:42
Reports on every change
Via · LoRaWAN
Last received –
Used for Physical security · log of entries and presence Send reading now LIVE SENSORLEAK_03
Leak detection · level 3 Water0 mm Place on the cable– Cable length42 m
Reports on every change
Via · LoRaWAN
Last received –
Used for Rule: water under the floor → alarm and the loop's valve closed Send reading now LIVE SENSORRPP_03
Row power panel · level 3 Load116.3 kW L1177 A L2167 A L3162 A Capacity used73% Branches10 / 10
Reports every minuteevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: branch > 90% → overload alarm · phase balancing Send reading now LIVE SENSORSMOKE_03
Smoke · level 3 Obscuration0.02 %/m Temperature rise0.1 °C/min StateClear
Reports on every change
Via · LoRaWAN
Last received –
Used for Rule: smoke or a sudden temperature rise → alarm and suppression armed Send reading now LIVE SENSORGAS_03
Gas suppression · level 3 Pressure42 bar StateArmed Cylinders4 / 4
Reports every 15 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Measurement history and trends Send reading now LIVE SENSORDOOR_03
Door · control room DoorClosed People inside1 Last entry13:42
Reports on every change
Via · LoRaWAN
Last received –
Used for Physical security · log of entries and presence Send reading now LIVE METERPOWER_01
Electrical load Load412.6 kW Today6184 kWh Peak431.2 kW
Reports every 15 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: peak > 450 kW → peak management · cost KPI Send reading now LIVE SENSORPQ_01
Power quality · feed A Voltage231 V THD3.1% cos φ0.97 Frequency50.00 Hz Current612 A Events today0
Reports every minuteevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Outage, sag and swell with a timestamp → alarm correlation Send reading now LIVE SENSORGEN_01
Generator Output0 kW StateStandby Running hours312 h Engine38 °C Voltage0 V Frequency0.0 Hz
Reports every minuteevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: mains failure → start · service every 500 running hours Send reading now LIVE SENSORFUEL_01
Fuel tank Level86% Autonomy41 h LeakDry
Reports every 15 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: level < 40% → fuel order · leak → alarm Send reading now LIVE SENSORUPS_01
UPS Load58% Output348.8 kW Input231 V SourceMains BypassOff Alarms0
Reports every minuteevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: load > 90% or bypass → alarm · redundancy Send reading now LIVE SENSORBATT_01
UPS batteries Charge100% Runtime14 min SoH94% Temperature24.1 °C String voltage544 V Cell resistance3.2 mΩ
Reports every 5 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for KAI: failure forecast from cell resistance and temperature Send reading now LIVE SENSORCHW_01
Cooling water Supply17.8 °C Return23.9 °C
Reports every minuteevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Rule: supply > 22 °C → second cooling tower on Send reading now LIVE SENSORPUMP_01
Circulation pumps Flow49.3 m³/h Pressure2.8 bar Cooling delivered349 kW Pump power11.2 kW StateRunning Aisle Δp12 Pa
Reports every minuteevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for Cooling delivered and cooling energy for PUE · pressure diagnostics Send reading now LIVE SENSORTOWER_01
Cooling towers Fan speed62% Tower 1Running Tower 2Standby Power18.4 kW COP6.9 Next service38 days
Reports every minuteevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for KAI: cooling-equipment failure forecast from fan speed and power Send reading now LIVE METERWATER_01
Water use Flow0.15 m³/h Today2.1 m³ Pressure3.4 bar
Reports every 15 minevery few seconds in this demo
Via · LoRaWAN
Last received –
Used for WUE and cost control of water use Send reading now 600 mm 600 mm A Data halls B Cooling C Access · car park D Power supply
KUEM · Nexavia showcase room Model 60 × 60 cm · 4 modules
Building the interactive model
Loading the datacenter model
0 %